HK DPH 4 710 DR SPIL

4/3-Wegeventil NG 25, ohne Pilotventil
Tipo
4/3 
Sobreposição
negativo (aberto) 
Tipo de pistão
0 [PB/AT]-[ABPT]-[PA/BT] 
Download PDF
Register now to get access to our online shop

Register now and access our complete product range and many exclusive services.

Product details for

HK DPH 4 710 DR SPIL

Tipo
4/3
Sobreposição
negativo (aberto)
Tipo de pistão
0 [PB/AT]-[ABPT]-[PA/BT]
Modelo
retorno por mola, gerador de pressão de controle

Characteristics

Pressão operacional
  • P, A, B: máx. 350 bar / T: máx. 210 bar 
Modelo
  • válvula direcional 4/3 (sem válvula piloto) 
  • pilotada 
Conexão
  • ISO/Cetop 08 NG 25 
Fluxo volumétrico
  • máx. 650 l/min (respeitar características) 
Fixação
  • 6 unid. parafuso sextavado interior M 12 x 50 12.9 
  • jogo de parafusos HK M12 50 para 1 válvula básica, para empilhamento vertical com placas intermédias devem ser utilizados parafusos mais compridos de acordo com as respectivas alturas das placas 
Customs tariff number
  • 84812010 
All characteristics

Product description

Notes
Os orings (NBR 90 Shore A) para a superfície de ligação da válvula podem ser encomendados separadamente como peças de reposição com o seguinte código de artigo: 4 unis OR28.17-3.53N90 e 2 unids OR13.94-2.62N90
Description
These valves are actuated by a solenoid directional valve NG6 in leakage oil-reduced design (type HK DHE...P...) to be installed as a pilot valve.
Control is internal, but conversion to external is possible.
The minimum control pressure for correct function is 8 bar.
In the version with control pressure generator, an additional pressure drop is generated which ensures the minimum required control pressure for a correct switching function. The version with control pressure generator must be used if the pressure drop in the valve is below the minimum value of the control pressure.
Ordering information
outros circuitos e modelos, assim como fluxos volumétricos e limites de capacidade de comutação sob consulta

Product variants

4 Results
Show dimensional drawing
Identifier
Tipo
Sobreposição
Tipo de pistão
Modelo
4/3 
negativo (aberto) 
0 [PB/AT]-[ABPT]-[PA/BT] 
retorno por mola, gerador de pressão de controle 
4/3 
positivo (fechado) 
1 [PB/AT]-[A/B/P/T]-[PA/BT] 
retorno por mola 
4/3 
positivo (fechado) 
3 [PB/AT]-[ABT/P]-[PA/BT] 
retorno por mola 
4/3 
negativo (aberto) 
4 [PA/BT]-[A/B/PT]-[PB/AT] 
retorno por mola, gerador de pressão de controle 
tipo de pistão: [A/B/PT] = [A fechado/B fechado/P+T ligado]

Column selection

Tipo
Sobreposição
Tipo de pistão