HK 315L14 B35 4-6 IE4

E-MOTOR 400/690V 160,0KW 1490U B35 IE4
Product details for

HK 315L14 B35 4-6 IE4

P 50 Hz
160 kW
n 50 Hz
1 490 r/min
P 60 Hz
184 kW
n 60 Hz
1 490 r/min
LF 50 Hz
0,89
Factor IA / IN
7,5
η %
96
A
508 mm
B
1 155 mm
C
855 mm
H
315 mm
I 50 Hz
269 A
Ø E
550 mm
Ø Eixo D
80 mm
Ø F
660 mm
All characteristics

Characteristics

Temperatura ambiente
  • -20 °C até +40 °C 
Tipo de proteção
  • IP 55 
Material
  • corpo: alumínio 
  • carcaça: ferro fundido cinzento (a partir de HK160...) 
Modelo
  • modelo B3 / B5 
  • pés desmontáveis 
  • pés fixos (a partir de HK 160M4...) 

Descrição do produto

Notes
Caution! Measurement »B« can depending on design slightly vary in length.
Description
Self-cooling squirrel-cage energy-saving motors.
High Efficiency IE3 or Super Premium Efficiency IE4 according to (EG) 2019/1781.
Rated voltage 400/690 V 50 Hz, 460 V 60 Hz.
4-pin.
Voltage tolerance ±5 %.
All motors including thermal protection (PTC thermistor).

Product variants

17 Results
Show dimensional drawing
Identifier
P 50 Hz (kW)
n 50 Hz (r/min)
P 60 Hz (kW)
n 60 Hz (r/min)
P 50 Hz = nominal output at 400 V/50 Hz
P 60 Hz = nominal output at 400 V/60 Hz
n 50 Hz = nominal speed at 400 V/50 Hz
n 60 Hz = nominal speed at 400 V/60 Hz
I 50 Hz = nominal current at 400 V/50 Hz
LF 50 Hz = cos phi power factor at 50 Hz
Factor IA / IN = start-up current IA / Nominal current IN
η = efficiency in % (at full load)

Shows 10 of 17

Column selection

P 50 Hz (kW)
n 50 Hz (r/min)
P 60 Hz (kW)
n 60 Hz (r/min)
LF 50 Hz
Factor IA / IN
η %
A (mm)
B (mm)
C (mm)
H (mm)
I 50 Hz (A)
Ø D shaft (mm)
Ø E (mm)
Ø F (mm)
P 50 Hz = nominal output at 400 V/50 Hz
P 60 Hz = nominal output at 400 V/60 Hz
n 50 Hz = nominal speed at 400 V/50 Hz
n 60 Hz = nominal speed at 400 V/60 Hz
I 50 Hz = nominal current at 400 V/50 Hz
LF 50 Hz = cos phi power factor at 50 Hz
Factor IA / IN = start-up current IA / Nominal current IN
η = efficiency in % (at full load)